Target Sample Submission Guidelines
Total RNA Sample:
Quality of total RNA: All RNA samples should meet assay quality standards to ensure
the highest quality RNA is hybridized to the gene expression arrays. User should
run the initial total RNA on an agarose gel or bioanalyzer to examine the ribosomal
RNA bands. 260/280 absorbance readings should be measured for total RNA. Acceptable
260/280 ratios fall in the range of 1.8 to 2.1.
Amount of total RNA: Depending on different platform to use, different amount is
required. Generally, 1-5 total RNA is needed. The RNA concentration should be greater
than 0.1ug/ul (add RNase-free water to adjust concentration if necessary).
Please submit a copy of the photograph of your total RNA on the agarose gel electrophoresis
or bioanalyzer printout, and 260/280 and 260/230 absorbance reading together with
the sample(s).
Total RNA Sample:
Quality of DNA: User should run the initial DNA on an agarose gel or bioanalyzer
to examine the ribosomal RNA bands. 260/280 absorbance readings should be measured
for genomic DNA. Acceptable 260/280 ratios fall in the range of 1.6 to 1.8.
Amount of DNA: 500ng DNA is required. The DNA concentration should be 50ng/ul. DNA
should be dissolved in DNase-free water or low EDTA TE buffer.
Please submit a copy of the photograph of your DNA on the agarose gel electrophoresis
or bioanalyzer printout, and 260/280 and 260/230 absorbance reading together with
the sample(s).
Shipping:
Overnight shipment using a commercial carrier (FedEx or UPS, etc) is required.
1. For tissues and cells: Keep in dry ice for frozen tissues and
cell pellets. Never let it thaw, so make sure the dry ice is enough. For RNA, later
kept tissues or cells, use ice pads instead.
2. For total RNA and Genomic DNA: Ship with dry ice.
Array Printing Sample Submission Guidelines
DNA (cDNA or oligos):
Quality of oligos: 260/280 absorbance readings should be measured using a spectrophotometer.
Acceptable 260/280 ratios fall in the range of 1.8 to 2.1.
of oligos: At least 50ul in DNase-free water is needed. The DNA concentration should
be between 0.1 and 0.5ug/ul (add DNase-free water to adjust each sample to same
concentration).
Both DNA or protein samples should be kept in 96-well microtiter plates.
A sample sheet with sample names should be included with the shipment. Also please
specify number of arrays and number of replicated spots on the arrays.
Protein/Antibodies:
Proteins/Antibodies should be dissolved in printing buffer (1x PBS/0.05 BSA) to
0.5mg/ml or higher. At least 50 ul in volume is required.
Both DNA or protein samples should be kept in 96-well microtiter plates.
A sample sheet with sample names should be included with the shipment. Also please
specify number of arrays and number of replicated spots on the arrays.
Shipping:
Overnight shipment with ice pad using a commercial Carrier (FedEx or UPS, etc)
is required.