Ten Things That Can Kill Your PCR

A blank PCR gel is one of the most aggravating things in molecular biology. We've all had PCRs work one day, then fail inexplicably the next. And we've all banged our heads against a wall trying to figure out what went wrong. If your gels are turning up blank, check out this list of things that can kill your PCR -- and get your experiments working! Nowhere is the adage "an ounce of prevention is worth a pound of cure" more applicable than PCR. Depending on your level of PCR expertise, some of these hints may seem obvious. But how many times have you kicked yourself because you overlooked the obvious? Whether you're an expert or a novice, any of these may be just what you're searching for to get your PCR working.

1. Using too much dNTP or degraded dNTP: Too much dNTP can inhibit your PCR reaction. A concentration between 40 - 200 uM is the optimal range. Also, dNTPs are sensitive to repeated freeze-thaw cycles. Use small aliquots when you get a fresh batch, and turn over your stock frequently since dNTPs stored at -20 C will eventually go bad.


2. Not mixing MgCl2: Magnesium chloride solutions form a concentration gradient when frozen and must be vortexed before use.


3. Using the wrong MgCl2 concentration: Every PCR reaction has an optimal MgCl2 concentration range, usually between 1 - 4 mM. Mg2+ ions form complexes with dNTPs and can also act as a co-factor for polymerases, so you'll need to try several conditions to optimize your concentration.


4. Inhibitors in your reaction: Ensure you know your source of DNA. Chloroform, phenol, EDTA, ionic detergents (SDS and Sarkosyl), xylene cyanol, bromophenol blue, and ethanol -- among many other things -- can inhibit PCR. An extra clean-up step on your template may do the trick. Also, specific polymerases can be more susceptible to certain substances, so check your polymerase for possible inhibitors.


5. Poor quality mineral oil: Lower-grade preparations may contain nucleases that can kill your PCR. Also, avoid autoclaving your mineral oil if possible. Exposure to high heat may cause reaction-inhibiting hydrocarbons to form. Similarly, do not irradiate mineral oil with UV for long periods.


6. Using too much enzyme: Excess enzyme in your PCR can smear PCR products. Most people seem to use 0.5 ul of their stock Taq per reaction, but that may contain more than necessary for your particular PCR reaction.


7. Using the wrong primer concentration: You won't see any product if you have too little primer. Use too much primer, and you may get primer dimerization and not enough amplification. Stay within 0.1 - 1.0 uM of primer.


8. Using the wrong PCR program: Make sure the program you selected on your PCR machine is the one you want! It only takes a slip of a finger, or some klutz, to alter your program on a typical PCR machine. Check your program while cycling to make sure it's what you want.


9. Using excess or insufficient template: Too much template can inhibit PCR by binding all the primers. Too little template and amplification may not be detectable. For 25 - 30 cycles, 104 copies of the target sequence are sufficient.


10. Using a poor primer design: While primer design can seem like black art, avoid obvious errors like self-complementarity, complementarity between paired primers, or excessively long oligos (>30 bp). Making a new primer next to a suspect can often solve the problem and be faster and cheaper than trying numerous variations in reaction conditions. Of course, this list is by no means comprehensive. Like any experiment, many things can go wrong. If you have anything you'd like to add, we'd love to know about it.


May all your PCRs work the very first time!