⌘ Services

Imaging & Spatial Biology Probes

Custom DNA, RNA, PNA and specialty oligonucleotide probes for chromosome visualization, RNA imaging, multiplex FISH and spatial biology—from target sequence and probe architecture to labeling chemistry, synthesis and analytical QC.

DNA & Chromosome FISH smFISH · MERFISH · seqFISH Oligopaint PNA FISH Fluorescent & NIR Labels

Imaging probes built around the biological question

Different targets call for different probe architectures. Imaging a single RNA molecule, a chromosome region, or thousands of transcripts requires different approaches to sequence selection, probe-set design, labeling and detection.

Bio-Synthesis supports custom DNA, RNA, PNA and chemically modified oligonucleotide probes for FISH, multiplex imaging, spatial transcriptomics and specialized microscopy workflows. Our team can review synthesis feasibility, modification placement, purification and analytical QC. Imaging performance is application-dependent and should be verified in the intended assay.

01 / Chromosome & DNA imaging

FISH, Oligopaint, centromere and telomere visualization

02 / RNA localization & detection

smFISH, RNA imaging and transcript localization

03 / Multiplex & spatial biology

MERFISH, seqFISH and spatial transcriptomic probe sets

04 / Advanced imaging & signal detection

DNA-PAINT, STORM, HCR and bDNA signal amplification

DNA & chromosome imaging Oligopaint · Chromosome painting · PNA FISH
RNA & spatial imaging smFISH · MERFISH · seqFISH · Spatial probes
Signal chemistry Fluorescent · NIR · Conjugates · Amplification

Explore Our Imaging Probe Services

Find the right probe for your research. Browse our 12 imaging services by application, compare design considerations, and visit each dedicated service page for more information.

Labels & Conjugation 01

Fluorescent Imaging Probes

Fluorophore-labeled DNA, RNA and specialty oligonucleotides for microscopy, hybridization and multicolor detection.

Design considerations Visible-spectrum dyes, terminal/internal labeling, dye spacing
Explore service details →
Labels & Conjugation 02

Near-Infrared (NIR) Imaging Probes

Far-red and near-infrared labeled oligonucleotides for optical imaging and preclinical research.

Design considerations Spectral matching, dye hydrophobicity, stability and controls
Explore service details →
RNA Imaging 03

smFISH Probes

Multi-probe sets designed to visualize individual RNA transcripts in fixed cells and tissues.

Design considerations Probe tiling, transcript specificity, accessibility, dye brightness
Explore service details →
RNA Imaging 04

RNA Imaging Probes

Custom RNA-targeting probes for localization, trafficking and selected live-cell imaging strategies.

Design considerations RNA target region, accessibility, background and delivery
Explore service details →
Spatial & Multiplex 05

MERFISH Probes

Encoding and readout oligonucleotide sets for multiplexed error-robust RNA imaging workflows.

Design considerations Barcode architecture, orthogonality and decoding workflow
Explore service details →
Spatial & Multiplex 06

seqFISH Probes

Custom sequential hybridization probe sets for high-plex transcript detection and spatial mapping.

Design considerations Hybridization rounds, readout specificity and channel compatibility
Explore service details →
Spatial & Multiplex 07

Spatial Transcriptomic Probe Sets

Targeted oligonucleotide probe panels for spatially resolved RNA analysis and compatible imaging workflows.

Design considerations Platform-specific design, probe-panel balance and validation
Explore service details →
DNA & Chromosome 08

Oligopaint Probes

Sequence-defined DNA FISH probe libraries for genomic loci, chromosome regions and 3D genome studies.

Design considerations Genomic uniqueness, repeat masking, tiling density and labeling
Explore service details →
DNA & Chromosome 09

Chromosome Painting Probes

Custom DNA probe collections for visualizing chromosomes or selected chromosome regions.

Design considerations Coverage, repetitive sequences, probe complexity and specificity
Explore service details →
DNA & Chromosome 10

Telomere & Centromere PNA FISH Probes

Custom PNA FISH probes for telomeric repeats and selected centromeric targets in chromosome imaging and cytogenetic research.

Design considerations Target repeat sequence, chromosome specificity, fluorophore selection and hybridization conditions
Explore service details →
Labels & Conjugation 11

Oligonucleotide Imaging Probe Conjugates

Specialized imaging-label attachment, custom reactive handles and multi-label conjugate architectures.

Design considerations Conjugation chemistry, labeling position, purification and QC
Explore service details →
Labels & Conjugation 12

Super-Resolution Imaging Probes

Custom oligos and dye strategies for DNA-PAINT, STORM and other super-resolution workflows.

Design considerations Docking/imager strands, photophysics and localization precision
Discuss a custom design →

Showing 12 of 12 services.

Explore Specialty Imaging Probe Technologies

Explore 11 specialized probe architectures and imaging strategies that complement our primary services. Expand a technology to review its design approach, typical applications and related services.

10 technologies shown
01 Fluorescent RNA Probes RNA Imaging

Representative design: Fluorophore-labeled RNA oligonucleotides (RNA chemistry), distinct from DNA probes designed to hybridize to RNA targets

Applications: RNA-based hybridization probes and selected RNA localization studies

Explore RNA Imaging Probes ↗
02 PNA Imaging Probes DNA & Chromosome

Representative design: Dye-labeled PNA probes

Applications: High-affinity FISH and telomere imaging

Explore PNA FISH Probes ↗
03 Molecular Beacon Imaging Probes RNA Imaging

Representative design: Fluorophore–hairpin–quencher probes

Applications: Conditional fluorescence and target-responsive imaging

Explore Molecular Beacon Probes ↗
04 Branched DNA (bDNA) Imaging Probes Signal Amplification

Representative design: Target-specific probes and branched amplification architecture

Applications: Signal-amplified RNA imaging

Explore bDNA Amplifier Probes ↗
05 HCR Imaging Probes Signal Amplification

Representative design: Initiator-bearing probes and fluorescent DNA hairpins

Applications: Enzyme-free hybridization chain reaction amplification

Discuss a custom imaging design ↗
06 DNA-PAINT Super-Resolution Probes Super-Resolution

Representative design: DNA docking strands and complementary fluorescent imager strands

Applications: Transient-binding single-molecule localization imaging

Discuss a custom imaging design ↗
07 STORM Imaging Probes Super-Resolution

Representative design: Photophysics-compatible fluorophore-labeled oligos

Applications: Single-molecule localization and nanoscale imaging

Discuss a custom imaging design ↗
08 Click-Functionalized Imaging Probes Labels & Conjugation

Representative design: Azide, DBCO, alkyne and other reactive oligo handles

Applications: Post-synthetic labeling and custom conjugation

Explore Imaging Probe Conjugates ↗
09 Live-Cell RNA Imaging Probes RNA Imaging

Representative design: Molecular beacons or other live-cell-compatible RNA probes

Applications: Dynamic RNA localization research

Explore RNA Imaging Probes ↗
10 Radiolabel-Ready Imaging Probes Labels & Conjugation

Representative design: Oligos with isotope-compatible conjugation handles

Applications: Specialized radiotracer development workflows

Discuss a custom imaging design ↗

Find the Right Imaging Probe for Your Application

Choose what you want to visualize, your imaging workflow and your preferred label. This tool offers a starting-point recommendation, not a validated experimental design.

smFISH Probes

For fixed-sample transcript visualization, a tiled smFISH probe set is a common starting point.

Design priorities

Transcript specificity, tiling, accessibility and fluorescence background.

Related technology

RNA Imaging Probes

Discuss This Design

Designed for Your Target. Built for Your Imaging Workflow.

Successful imaging starts with a probe that fits the target, sample and detection method. Bio-Synthesis works with researchers to evaluate sequence specificity, probe architecture, labeling chemistry and manufacturing requirements for custom DNA, RNA, PNA and specialty oligonucleotide probes.

Whether you need a single fluorescent probe or a multiplexed probe set, we help identify practical design and QC options that support your experimental goals.

Discuss Your Probe Design

One coordinated approach, from sequence to delivery

01
Target specificity Sequence selection, off-target assessment and accessible regions
02
Signal strategy Fluorophores, spectral compatibility, linkers and background
03
Probe architecture Single probes, tiled libraries and encoding/readout sets
04
Manufacturing & QC Synthesis feasibility, purification and agreed analytical testing
`

Custom chemistries

DNA · RNA · PNA · modified oligonucleotides

`

Flexible labeling

5′, 3′ and internal labels · specialty linkers

`

Scalable formats

Individual probes · multiplexed probe sets

From Consultation to Finished Imaging Probes

01 Consultation

Define the target, specimen, imaging platform, multiplexing needs and project goals.

02 Probe Design

Select target sequences, probe architecture, chemistry, labels and readout strategy.

03 Synthesis

Manufacture custom oligonucleotides and incorporate specified functional modifications.

04 Purification

Purify probes using methods suited to their chemistry and intended specifications.

05 Quality Control

Perform agreed analytical testing, such as identity and purity assessment, as applicable.

06 Delivery

Provide the finished probes with available QC documentation and handling guidance.

Why Choose Bio-Synthesis?

Imaging and spatial biology experiments often demand more than a standard fluorescent oligo. We bring together custom nucleic acid chemistry, probe design flexibility, and analytical expertise to help translate a research concept into a well-characterized probe.

One scientific partner. Multiple probe chemistries.

From conventional DNA and RNA probes to PNA, affinity-enhanced designs, specialty fluorophores, and complex labeled probe sets, our team helps align chemistry with the intended imaging workflow.

Custom synthesis · Labeling · Conjugation · Purification · Analytical QC

Custom Probe Chemistry

Flexible DNA, RNA, PNA, and modified oligo designs for specialized hybridization and imaging applications.

Application-Focused Design

Thoughtful selection of dye, probe architecture, spacing, and labeling strategy for your experimental readout.

Analytical Quality Control

Purification and identity testing options, including HPLC and mass spectrometry where appropriate for the construct.

Research-to-Development Support

Support for early feasibility work, custom probe sets, and scale-up planning as project requirements evolve.

Quality Systems & Manufacturing Support

ISO-Supported Oligonucleotide Manufacturing

Custom fluorescent imaging probes, PNA FISH probes, multiplex panels and spatial biology probe sets supported by controlled synthesis, purification, analytical quality control, documentation and project-specific packaging.

01 ISO 9001:2015 Quality management system
02 ISO 13485:2016 Medical-device quality management framework
03 ISO 14001-Aligned Environmental management practices
04 Analytical QC HPLC/UPLC, mass spectrometry where compatible, OD and CoA

Available QC and documentation are tailored to each project. ISO-supported manufacturing does not imply clinical diagnostic validation or guaranteed biological imaging performance.

FAQ

Do you offer both individual probes and multiplex probe sets?
We can evaluate single-probe constructs and multi-oligonucleotide probe sets. The feasible format, scale and QC depend on the imaging technology and target panel.
Can you help choose a dye and labeling position?
Yes. Dye choice and 5′, 3′ or internal attachment can be reviewed against instrument channels, photostability, background, target accessibility and linker requirements.
Are Oligopaint probes the same as chromosome painting probes?
Not exactly. Oligopaint describes a sequence-defined oligonucleotide FISH design approach. Chromosome painting describes the imaging application; Oligopaint libraries can be used for chromosome painting.
How are MERFISH, seqFISH and smFISH different?
smFISH typically uses multiple labeled probes to detect individual transcripts. MERFISH and seqFISH use multiplexed encoding and sequential imaging/readout strategies, with workflow-specific probe designs.
Can telomere and centromere PNA FISH probes be supplied with different dyes?
Dye and linker options can be reviewed for telomere or centromere targets based on the instrument and hybridization protocol. Centromere probe feasibility depends on the target repeat sequence and chromosome specificity; not all centromere FISH probes use PNA.
Do you guarantee imaging signal or biological performance?
Manufacturing specifications and analytical QC can be agreed upon, but imaging signal and biological results depend on sample preparation, target abundance, instrument settings and experimental conditions.

Bring Your Imaging Probe Design to Life

From a single fluorescent oligonucleotide to a complex multiplex imaging probe set, our team can review your target, probe architecture, labeling chemistry, synthesis requirements, and analytical specifications.
Partner with a Leader in Biosynthetic CDMO Solution

Partner with a Leader in
Biosynthetic CDMO Solution

01

Probe Design Consultation

Discuss your target sequence, sample type, imaging platform, fluorophore channels, and probe-set architecture.

smFISH Spatial imaging FISH
02

Synthesis & QC Review

Confirm labeling positions, linker chemistry, purification, analytical identity, final quantity, and feasibility.

HPLC Mass spectrometry Custom scale

Why Choose Bio-Synthesis

Trusted by biotech leaders worldwide for over 45 years of delivering high-quality, fast, and scalable synthetic biology solutions.